Tools and Materials:
 
1. Tools: cleaning cloth, wrenches, screwdriver, drill, insulating tape, epoxy resin
 
    Materials: C-LED module, switch power, connecting wire
    NOTE: KEEP OFF Water during installment.
 install 1
 
2. Check the ark to make sure it is OK, wipe off  dirties, keep the surface clean and dry.
install2
 
 
3. Install the C-LED with 5cm-8cm space in the ark, fixed the C-LED bottom with tape and screwdriver.
install3
NOTE:
* Red wire is anode, and white wire is cathode, the C-LED will not work with incorrect connection;
* With triangle install if have more C-LED modules.
 
 
4. Drill a hole between C-LED and switch power.
install 4
 
 
5. Connect C-LED to output of switch power, average quantity of loop wires, and the total volume should not exceed the switch power.
install 5
 
 
6. Check C-LED status after connecting to switch power, and joint the AC. If C-LED dos not work, please recheck the anode and cathode.
install 6
 
 
7. Use insulation caps in wire and connection dealing, fill up the empty spaces with epoxy or silica gel.
install 7
 
 
Ⅲ. Fault explanation:

PERFORMACE
POTENTIAL PROBLEMS
RESOLVEMENT
ALL C-LED DO NOT WORK
Damage of switch or no electricity
Turn on the switch or change another one
Converse the anode and cathode to C-LED
Reconnect the anode and cathode
Short circuit to C-LED
Reconnect and repair
PARTIAL
C-LED DO NOT WORK
Converse partial C-LED polarity
Reconnect with correct polarity
Short circuit for dirty end of C-LED wire
Rewrap the wire
ALL C-LED
OBSCURATION
 Low output DC 12V
Adjust or change power
C-LED quantity exceed the volume
Adjust each wire to available
C-LED FLICKER
Incorrect connecting of C-LED wire
Reconnect the incorrect wire
SHINNING
SPOT ON   THE LETTERS
The normal height of the ark is 10~12CM
Make another ark
Bad quality of acrylic board
Use good quality manufacturing
SHADOW ON THE LETTERS
Less quantity of C-LED
Add C-LED module
Mixed using of different C-LED
Use the same series of C-LED

 
SAIXING ELECTRIC S&T CO.,LTD reserved the right of final explanation of SAIXING products